I have had complete failure with an older linksys sipura spa 2002 and the same sip trunk. Introduction 1 introduction this sip configuration guide is a quick guide to assist you to connect audiocodes media gateways to the ippbx. I have both a pap2t and spa2002 connected to my system and the audio quality is noticeably better on the pap2t. Spa1001 firmware version 5 the linksys firmware version 5 release notes state that the spa1001 is supported, however, the latest version of the firmware on the sipura web site is 3. Due to licensing restrictions, firmware is not managed for cisco devices they must be updated manually.
Connect an analog phone to the phone 1 port on the spa2002. Once that code is downloaded you will need to unpack the zip file and then run. Sipura spa 2000 analog voip adapter the spa features two pots plain old telephone service ports for connection to existing analog phones, fax machines, pbx and key system communication platforms. Sipura spa3102 simplified users guide version manualzz. Sipura spa2002 configuration guide page 2 2 accessing the spa2002 to access the spa2002. Cisco keeps all firmware close to the heart and its darn near impossible to find it on any of ciscos sites. Upgrading firmware the latest firmware for the sipura spa3000 can be located on the sipura support site. Your spa2002 device must have f ir mware vers io n 3.
We also support asterisk pbx, trixbox and offer turnkey voip reseller business opportunities to let entrepreneurs and businesses resell voice over internet voip under their brand name. Then use it for 3060 days and decide if it has merit. It should be possible to get hvoipm working against your sipura spa 2000. We have seen instances where installing the spa2002 behind a firewall which blocks icmp packets causes problems with registration. Connect to the spa2002 by entering the devices ip address in the web browsers address bar. Konftel rtx sip dect solution wireless sip conference phone.
As youve asked for the source code, ill explain roughly how. Sep 18, 2012 i bought sipura spa2002 voip phone adapter about six years ago. Dec 17, 2007 i just received a linksys spa2102 vt from my voip provider and it has firmware 3. Jan 24, 2011 sipura spa 2000 analog voip adapter the spa features two pots plain old telephone service ports for connection to existing analog phones, fax machines, pbx and key system communication platforms.
Also the update enable field on the provisioning tab needs to be set to yes or it will ignore requests to upgrade the firmware. This will create a line extension between a sipura 1001 although 2000, 2002. Ive forwarded ports to my sipura spa2002 and even put the sipura in the dmz and still fail to register. Sipura firmware default admin username default admin password spa firmware with upgrade utility program download the firmware file to a local pc to upgrade your spa with currently supported releases. This free service allows you to easily configure a sipuralinksys spa series adaptor for a number of different services with known good configurations. Sipura technology spa2002 configuration manual pdf download. Since ive got about a dozen of these things, ive bought the bullet and built up a small collection of firmware and will provide you with instructions. Any provider using cisco phones on the broadsoft platform should know about the firmware issue cisco spa112spa122. You have a sipuralinksys spa2002, for other linksys devices, choose another device configuration wizard. I have had complete failure with an older linksyssipura spa2002 and the same sip trunk. Kf300wxvoip 1 rtx sip dect base 1 konftel 300wx conference phone more information. Inphonex is proud to support internet telephony equipment ip phones including sipura 2000, sipura 3000, cisco 186, linksys pap2 and other sip phone adaptors. There is one rather significant problem im having, however.
In order to upgrade the firmware of your router, you need to perform two steps. Im using v23 sp1 final std on a linksys wrt54gl v1. Spa1001 firmware version 5 voip tech chat dslreports forums. Sipura technology spa2002 configuration manual pdf. Sipura spa 2002 configuration guide outbound calling sipura technology spa 2000 users manual configuration guide sipura spa 2000. Linksys spa2002er frys voip tech chat dslreports forums.
With either of these phones, the same broadvoice coupon described above is included. Commpartners customer premise equipment page 12 of 24 3. The way i understand it is the spa 2100 is phasing out and replaced by spa 2102. To upgrade the firmware in your spa3102 download the latest firmware, unzip it and run the exe file provided.
Would it be possible to update the page the website redirects to so that it is a little more relevanthelpful. We have seen instances where installing the spa 2002 behind a firewall which blocks icmp packets causes problems with registration. Hello, i have accidently broken my spa2000 trying to get both lines working. Linksyssipura spa2002 voip adaptor login information gateway 192. Sipura spa2002 configuration guide outbound calling sipura technology spa2000 users manual configuration guide sipura spa2000. In particular there is a lot of background hiss from the spa2002 that is not present on the pap2t. We delete comments that violate our policy, which we encourage you to read. This free service allows you to easily configure a sipura linksys spa series adaptor for a number of different services with known good configurations. Firmware upgrade it is good to have your devices always updated to the latest available firmware. The sipura firmware update tool does not work if the spa has an admin password set. On incoming calls it either goes to voicemail or rings and then disconnects when you pickup other end hears fast busy.
Ciscos spa112 spa1xx series of products are the successors to the popular pap2 and pap2t line of adapters. The new firmware adds numerous functions to the router. Linksys sipura spa 2002 voip adaptor login information gateway 192. The sipura spa 2002 is supported for use with net2phone accounts when running the following firmware version only. When i clean up my folders of hardware documents, i saw this guide. It should be possible to get hvoipm working against your sipura spa2000. This means that it gets its ip address from your dhcp server automatically. Sipura also makes a phone, but there have been problems reported with the rubberized buttons sticking. To save the space and for reference purpose, i scan it and you can download it here. The problem with firmware for these things started when sipura sold out to cisco. The sipura spa 2002 dial plan field value needs to be changed using web interface. List of known atas that can accept direct ip dialling. Basically, there are two ways to figure out what a voip device is doing. Sipura spa 841 sipura spa sipura spa 1001 sipura spa 2000 sipura spa 2002 sipura spa 2100 sipura spa 3000 setup instructions for the linksys pap2 are can be found here, and should help you with configuring your device.
Connect an analog phone to the phone 1 port on the spa 2002. Setup your sipura 2002 for inphonex voip phoner service using internet telephony to make free voip calls. I made an upgrade with the wrong firmware off the internet product information product name. So if an admin password is set on your spa you should clear it for the upgrade, then put it back afterwards. Sipura spa841 sipura spa sipura spa1001 sipura spa2000 sipura spa2002 sipura spa2100 sipura spa3000 setup instructions for the linksys pap2 are can be found here, and should help you with configuring your device. Sipura spa 2002 configuration guide page 2 2 accessing the spa 2002 to access the spa 2002. In the example below the spa3102 is located at 192. Power over ethernet linksys router wrt54gl linksys spa 2002 linksys ap linksys eight dots network key password linksys wsb24 linksys router adress firmware upgrades for linksys wrt54g linksys ftp cannot access 192. Release notes for cisco spa2102 firmware version 5.
Sipura technology spa1001 pdf manual download for free. I went to sipura website, and saw the new firmware there. Spa1001 firmware version 5 voip tech chat dslreports. Jul 26, 2009 once the device reboots you can get to the configuration menu in a web browser by visiting the ip address of the sipura spa 2000. They all seem to behave the same way with regard to providing cpc on their fxs ports they seem to provide it on received calls, but not on placed calls. We have 1 sipura technology spa2002 manual available for free pdf download. Ive forwarded ports to my sipura spa 2002 and even put the sipura in the dmz and still fail to register. This guide is not a detailed installation manual and it does not cover all the. I would also suggest upgrading the firmware on the router to the latest build you can find. Please obtain the latest firmware from this guide provides instructions for configuring of device settings for easy access to the. Sipura 2002 is a high quality device that offers great voip. You have a sipura linksys spa 2002, for other linksys devices, choose another device configuration wizard.
This document is a configuration guide for the sipura spa2002. Before you download the firmware, make sure that your computer has an active internet connection. Sipura spa2002 voip phone adapter series specs cnet. When i went to sipura website, i found that the latest firmware for spa 2100 is 3. I will be concerned that i will have a sort of a phased out device. For instructions on obtaining the ip address, refer to section 2. Linksys spa2002 sipura spa2002 configuration wizard. Should i be upgrading to linksyss proprietary firmware or stick with sipuras proprietary firmware even tho. Using the telephone keypad, press the star key four 4 times. How to factory reset a sipura spa2000 to default settings. I just received a linksys spa2102 vt from my voip provider and it has firmware 3.
Sipura spa 2000 analog voip adapter itemsea youtube. In particular there is a lot of background hiss from the spa 2002 that is not present on the pap2t. Sipura spa2002 voip phone adapter series sign in to comment. To upgrade the firmware in your spa3000 download the latest firmware, unzip it and run.
I have both a pap2t and spa 2002 connected to my system and the audio quality is noticeably better on the pap2t. Should i be upgrading to linksyss proprietary firmware or stick with sipura s proprietary firmware even tho. Once the device reboots you can get to the configuration menu in a web browser by visiting the ip address of the sipura spa2000. The sipura spa2002 is supported for use with net2phone accounts when running the following firmware version only. I bought sipura spa2002 voip phone adapter about six years ago. Page 8 sipura spa2002 configuration guide important you must have a different account and pin for line 1 and line 2. Searching around the site for the firmware is hard but i eventually found the one for the spa3102 but could not find the firmware for the spa3000. Once done, reconnect to the network, hit linksys and download the newest spa2002 firmware 3.